Skip to Content

Biosafety Cabinet Class II B2 NovaSafe Opti Plus 6 Ft (Model - 440415)

https://ambinova-technologies-pvt-ltd4.odoo.com/web/image/product.template/1797/image_1920?unique=9a0037b

Model - 440415 , HSN- 84198990

* Stand is not Incuded
HSN -  84198990

₹ 0.00 0.0 INR ₹ 0.00  Tax Excluded

₹ 8,84,581.00  Tax Excluded

  • MOC Internal Body
  • MOC External Body
  • Size

This combination does not exist.

New Launch
MOC Internal Body: White smooth coating
MOC External Body: Powder Coated Steel
Size: 6ft

Brochure/Catalogue:

Description


NovaSafe Opti Plus


Precision Protection

Smart Performance 

Essential Value.

 

Engineered for modern laboratories, the Novasafe Opti Plus delivers reliable Class II Type A2 biosafety protection with an optimal balance of performance, efficiency, and affordability. Designed using advanced airflow engineering and high-efficiency HEPA filtration, it ensures maximum operator safety, product integrity, and environmental protection. With a focus on simplicity, energy efficiency, and robust construction, Novasafe Opti Plus is ideal for laboratories seeking trusted biosafety performance without unnecessary complexity. Powered by intelligent control systems and stable AC blower technology, it maintains consistent airflow conditions critical for contamination-free operations.  

Features


Energy-Efficient AC Blower System

The Novasafe Opti Plus Series features a precision-engineered AC blower system for stable airflow, reliable containment, and energy-efficient performance in demanding laboratory environments.

Advanced Touchscreen Micro PLC Control System

Featuring a 7-inch touchscreen and micro PLC control, the system enables intuitive operation, multiple working modes, and real-time monitoring with integrated alarms and status indicators on a single interface.  

Quick-Access HEPA Filtration System 

Designed for service efficiency, the front-access HEPA filter system enables single-person filter replacement without specialized tools, reducing downtime and maintenance complexity.

Real-Time Downflow Monitoring System  

An advanced downflow velocity sensor provides continuous real-time airflow monitoring, ensuring consistent laminar flow, enhanced protection, and reliable performance for critical laboratory applications.

Automatic Downflow Control System

The Novasafe Opti Plus features intelligent automatic airflow control for consistent downflow velocity, ensuring stable laminar airflow, reliable containment, and continued biosafety compliance.

Paper Catch Protection System 

A protective screen within the rear return plenum prevents wipes, tissues, and debris from entering the blower assembly, enhancing system reliability and longevity.  

Pass-Through Utility Ports

Two (2) 70 mm ports on sidewalls allow safe routing of cables and tubing without compromising airflow integrity or containment performance.

Double-Wall Negative Pressure Plenum 

A fully enclosed double-wall plenum design surrounds contaminated zones under negative pressure, eliminating leakage risks from filter seals, gaskets, or structural joints—ensuring maximum biosafety assurance.

Factory-Calibrated Airflow System 

Airflow velocities are preset and calibrated during manufacturing to comply with regulatory standards, ensuring consistent inflow and downflow performance without user adjustment errors.

Full-Perimeter Air Intake System

The surround air intake grille design eliminates dead zones by capturing contaminated air across the entire work opening, maintaining uniform containment and operator protection.

Integrated Electrical Safety 

Internal electrical outlets are strategically positioned and protected to minimize exposure risks and ensure safe operation within the work zone.

Heavy-Duty Stainless Steel Interior

Constructed with a one-piece SS 304 liner featuring coved corners, the cabinet ensures easy cleaning, corrosion resistance, and long-term durability.

Ergonomic Operator Design 

10 Deg Angled front sash for optimal visibility . 

Narrow front grille to maximize workspace . 

Frameless sash for unobstructed access . 

SS 304 armrest ( Optional ) for operator comfort and proper airflow discipline . 

Designed to reduce fatigue and improve workflow efficiency.


High-Efficiency HEPA Filtration (H14) 

Equipped with Class H14 HEPA filters, delivering >99.995% efficiency at 0.3 µm, ensuring superior protection for personnel, product, and environment.

Three-Position Smart Sash System

This features an intelligent three-position sash system designed to enhance safety, compliance, and operational control : 

Sash Closed Mode : Fully closed position for secure shutdown, enabling safe UV operation and energy conservation.

Sash Safe Position (8-inch / 200 mm) : Factory-defined working sash opening height ensuring optimal inflow velocity and certified containment performance. 

Sash Unsafe Position Alert : Any deviation from the safe height triggers a visual and/or audible alarm, helping maintain proper operating conditions at all times.


Additional Features


Robust External Component Design

Critical components such as lighting systems, electrical modules, and manual switches are mounted outside the contaminated airflow path, enabling safe servicing without decontamination procedures.Automatic Shut-Down System Automatically turns off the UV, blower and lighting when the sash is fully closed, enhancing safety, conserving energy, and ensuring proper operation. Ensures operator safety and correct usage at all times.

International Compliance

Designed in accordance with EN 12469 standards, ensuring globally recognized levels of performance, containment, and safety.

Automatic Safety Interlock System  

Activates blower and lighting when sash is opened. 

Automatically disables UV during operation. 

Restores UV function when sash is fully closed. 

Ensures operator safety and correct usage at all times.


HEPA Filtration System

 The Novasafe Opti uses advanced H14 HEPA filtration to provide high-level protection for personnel, products, and the environment. It captures ≥99.995% of particles at 0.3 microns, ensuring a clean workspace. The special seal design prevents air leakage, while the durable aluminum frame maintains long-term stability. Its separator-free design improves airflow, and front-access filter replacement allows quick, safe, single-operator maintenance with minimal downtime.

Airflow Stability & Energy Optimization 

The Novasafe Lite is engineered with a precision-balanced airflow system, ensuring uniform downflow and exhaust distribution across the work area. 


Key Features


Optimized Air Distribution 

Carefully designed plenum and diffuser system ensures even airflow across the entire work surface, enhancing containment performance. 

Extended Filter Life 

Uniform airflow loading reduces localized stress on filters, helping to prolong HEPA filter lifespan and maintain efficiency over time. 

Stable Airflow Performance 

The blower system is tuned to maintain consistent inflow and downflow velocities, ensuring compliance with biosafety standards even under varying operating conditions.

Energy-Conscious Operation

The system is designed for efficient airflow generation with controlled power consumption, delivering a balance between performance and operating cost.


Technical Specifications



Classification

Class

II


Type

B2

Dimensions

Exterior Dimensions without stand W x H x D (mm)

1988 x 1601 x 884    


Exterior Dimensions with stand W x H x D (mm)

1988 x 2321 x 884   


Interior Dimensions W x H x D (mm)

1828 x 700 x 630     

Electrical Data

Voltage

220V


Frequency

50Hz


Energy Consumption (Watt)

690  

 Filter

Supply Filter

H14

 

Efficiency

≥99.995%


Exhaust Filter

H14


Efficiency

≥99.995%

Certification

CE/EN 12469/ISO 14644/IEC 60601


Ergonomics & Utilities

LED Light

800lux


UV Light

254nm


Gas Valves

Yes


Pass-Through Utility ports

70mm (2 nos)  


Electrical Switch & Socket

16Amp (1 nos) IN type

Display


7 inch Touch Screen Display

Feature

Operation Type

PLC


UV Hour Meter

Yes


Velocity Sensor

Yes


Sash Opening Sensor

Yes


Pressure Sensor

Digital pressure sensor  


Hepa Life Indication

Yes


UV Life Indication

Yes

Work Aperture

Sash Opening Hight

8”


Sound Level

<60dB


Sash Material

Toughend Glass


Sash Thickness

6mm

Air Circulation

Exhaust Volume Percentage

100 


Recirculation Volume Percentage

0

Air Velocity

Downflow Velocity

0.25 to 0.40m/s  


Inflow Velocity

0.51m/s

Blower

Blower Type

AC

MOC

Internal work Surface

SS304


Internal wall

Powder Coated Steel 


External body

Powder Coated Steel

Stand

Type

Manual Stand with Custor wheel / Adjustable foot


MOC

Powder Coated Steel / SS304




Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.